During asbestos cement sheet removal and remediation works, new metal roofing is typically installed along with carefully designed drainage systems for rainwater runoff. However, in practice, the condition of the concrete roof beams is often overlooked, despite having been exposed for decades to weathering and chemical degradation.
Carbonation: the invisible enemy
Carbonation is a natural yet insidious process: carbon dioxide (CO₂) from the air penetrates the concrete and reacts with calcium hydroxide, gradually lowering the pH from initial values of around 13 to 11 or less. At these levels, the reinforcing steel loses its alkaline protection and becomes vulnerable to corrosion.
The corrosion of the reinforcement leads to a volumetric expansion of up to seven times its original size, creating intense internal stresses that cause cracking, delamination, and spalling of the concrete cover. The result? A weakened structure with compromised structural integrity.
Precast Y-beams in prestressed concrete: hidden vulnerabilities
In many industrial buildings, Y-shaped beams made of prestressed concrete are a common structural solution. While the central core is usually protected by a thick concrete cover, the lateral bearing flanges have thinner layers, making them especially susceptible to carbonation. After 20 years of service, these components often show signs of deterioration – whether visible or hidden – that can compromise their load-bearing capacity, particularly under exceptional loads such as snow or wind.
Structural effects of carbonation
• Loss of internal cohesion in the concrete
• Gradual reduction of mechanical strength
• Corrosion of reinforcement and loss of bond
• Cracking and surface spalling in exposed areas
Structural risks under overload conditions
Installing a new roof on deteriorated beams can lead to serious issues:
• Localized failure of supporting beams
• Permanent deformations and risk of collapse
• Compromised slab and propagation of structural damage
The solution: HYDROSTOP FILM
To effectively counter carbonation, it is essential to use certified systems compliant with EN 1504-2.
HYDROSTOP FILM is a specialized liquid-applied product, CE-marked and compliant with the PI-MC-IR system for the protection of concrete structures. Once applied, it forms a waterproof barrier against water and CO₂, preventing degradation and significantly extending the service life of the structure.
Advatages of HYDROSTOP FILM
- CE marked - compliant with EN 1504-2 and European standards
- Excellent adhesion -suitable for all types of concrete surfaces
- Complete waterproofing - protection against CO₂ and weathering agents
- Fast application -up to 3,000 m² per day by spray
Cycle of application
Before starting the application, all surfaces must be thoroughly cleaned. Use a wet/dry vacuum to remove water and debris from the channels. Allow a few days of sun to ensure the concrete channels are completely dry, and check that the moisture level is below 2%.
1. Priming the substrate
Apply a first coat of HYDROSTOP BASE, diluted 1:3 with water (300%), using a roller, sprayer, or other suitable method. This step promotes adhesion of the subsequent waterproofing cycle to the substrate.
Consumption: 0,10 kg/m²
2. Creating the waterproof coating
Once the primer is dry, apply a uniform layer of pure HYDROSTOP FILM, using a roller or spray system depending on the surface morphology.
Consumption: 0,8 kg/m²
3. Embedding the reinforcement fabric
While the product is still wet, embed the HYDROFLEX fiberglass mesh to ensure uniform distribution and prevent air bubbles. Use a hand roller or brush to press the mesh into place. Apply the fabric in sections of no more than 10 meters, with an overlap of 3–5 cm between strips. Pay special attention to perfect bonding at overlaps, especially around channels and joints.
4. Finishing layer
Once the mesh is properly embedded, apply a second coat of HYDROSTOP FILM to fully saturate the reinforcement and form the final waterproof and anti-corrosion membrane.
Consumption: 0,8 kg/m²
